YH10W-33
- Rated VoltageRated Voltage额定电压
- 3-42kV
- Creepage DistanceCreepage Distance爬电距离
- 180-1160mm
- MaterialMaterial材料
- Polymer/Silicone rubberPolymer/Silicone rubber聚合物/硅橡胶
- FunctionFunction功能
- Lightning protectionLightning protection防雷
- CertificationCertification认证
- ISO9001/CQC
Metal-oxide surge arrester(Lightning arrster, polymer surge arrster)
Model:YH10W-33
Specifications:
1.ISO9001 quality management system
2.Own test laboratory
3.To provide the corresponding product components
4.The technical performance is accordding to IEC60099-4 and IEEE(ANSI)C62.11
5.Exportation design
Main Technical Parameter
Rated voltage r.m.s: 33kV
Nominal discharge current:10kA
Maximun continous operating voltage(Uc)(kV):28.1kV
Residual voltage at:
1/4μ s lightning current impulse residual voltage(kV):107.3
8/20μ s lighting current impulse residual voltage(kV):97.5
30/60μ s switching current impulse residual voltage(kV): 81.9
Long duration current impulse withstand:
2ms rectangular current(A):250
Operating duty:
4/10u s high current impulse(kA):100
Creepage distance(mm):1000mm
Dimension:465*211mmMetal-oxide surge arrester(Lightning arrster, polymer surge arrster)
Model:YH10W-33
Specifications:
1.ISO9001 quality management system
2.Own test laboratory
3.To provide the corresponding product components
4.The technical performance is accordding to IEC60099-4 and IEEE(ANSI)C62.11
5.Exportation design
Main Technical Parameter
Rated voltage r.m.s: 33kV
Nominal discharge current:10kA
Maximun continous operating voltage(Uc)(kV):28.1kV
Residual voltage at:
1/4μ s lightning current impulse residual voltage(kV):107.3
8/20μ s lighting current impulse residual voltage(kV):97.5
30/60μ s switching current impulse residual voltage(kV): 81.9
Long duration current impulse withstand:
2ms rectangular current(A):250
Operating duty:
4/10u s high current impulse(kA):100
Creepage distance(mm):1000mm
Dimension:465*211mmMetal-oxide surge arrester(Lightning arrster, polymer surge arrster)
Model:YH10W-33
Specifications:
1.ISO9001 quality management system
2.Own test laboratory
3.To provide the corresponding product components
4.The technical performance is accordding to IEC60099-4 and IEEE(ANSI)C62.11
5.Exportation design
Main Technical Parameter
Rated voltage r.m.s: 33kV
Nominal discharge current:10kA
Maximun continous operating voltage(Uc)(kV):28.1kV
Residual voltage at:
1/4μ s lightning current impulse residual voltage(kV):107.3
8/20μ s lighting current impulse residual voltage(kV):97.5
30/60μ s switching current impulse residual voltage(kV): 81.9
Long duration current impulse withstand:
2ms rectangular current(A):250
Operating duty:
4/10u s high current impulse(kA):100
Creepage distance(mm):1000mm
Dimension:465*211mm