YH10W-33

YH10W-33
  • Rated VoltageRated Voltage额定电压
  • 3-42kV
  • Creepage DistanceCreepage Distance爬电距离
  • 180-1160mm
  • MaterialMaterial材料
  • Polymer/Silicone rubberPolymer/Silicone rubber聚合物/硅橡胶
  • FunctionFunction功能
  • Lightning protectionLightning protection防雷
  • CertificationCertification认证
  • ISO9001/CQC

Metal-oxide surge arrester(Lightning arrster, polymer surge arrster)
Model:YH10W-33
Specifications:
1.ISO9001 quality management system
2.Own test laboratory
3.To provide the corresponding product components
4.The technical performance is accordding to IEC60099-4 and IEEE(ANSI)C62.11
5.Exportation design

Main Technical Parameter
Rated voltage r.m.s: 33kV
Nominal discharge current:10kA
Maximun continous operating voltage(Uc)(kV):28.1kV

Residual voltage at:
1/4μ s lightning current impulse residual voltage(kV):107.3
8/20μ s lighting current impulse residual voltage(kV):97.5
30/60μ s switching current impulse residual voltage(kV): 81.9

Long duration current impulse withstand:
2ms rectangular current(A):250

Operating duty:
4/10u s high current impulse(kA):100

Creepage distance(mm):1000mm
Dimension:465*211mmMetal-oxide surge arrester(Lightning arrster, polymer surge arrster)
Model:YH10W-33
Specifications:
1.ISO9001 quality management system
2.Own test laboratory
3.To provide the corresponding product components
4.The technical performance is accordding to IEC60099-4 and IEEE(ANSI)C62.11
5.Exportation design

Main Technical Parameter
Rated voltage r.m.s: 33kV
Nominal discharge current:10kA
Maximun continous operating voltage(Uc)(kV):28.1kV

Residual voltage at:
1/4μ s lightning current impulse residual voltage(kV):107.3
8/20μ s lighting current impulse residual voltage(kV):97.5
30/60μ s switching current impulse residual voltage(kV): 81.9

Long duration current impulse withstand:
2ms rectangular current(A):250

Operating duty:
4/10u s high current impulse(kA):100

Creepage distance(mm):1000mm
Dimension:465*211mmMetal-oxide surge arrester(Lightning arrster, polymer surge arrster)
Model:YH10W-33
Specifications:
1.ISO9001 quality management system
2.Own test laboratory
3.To provide the corresponding product components
4.The technical performance is accordding to IEC60099-4 and IEEE(ANSI)C62.11
5.Exportation design

Main Technical Parameter
Rated voltage r.m.s: 33kV
Nominal discharge current:10kA
Maximun continous operating voltage(Uc)(kV):28.1kV

Residual voltage at:
1/4μ s lightning current impulse residual voltage(kV):107.3
8/20μ s lighting current impulse residual voltage(kV):97.5
30/60μ s switching current impulse residual voltage(kV): 81.9

Long duration current impulse withstand:
2ms rectangular current(A):250

Operating duty:
4/10u s high current impulse(kA):100

Creepage distance(mm):1000mm
Dimension:465*211mm

相关产品